Hydraulics and sanitation

Pressure pipe head loss (Darcy-Weisbach)

Inputs

Formulas

V = Q / (π D²/4) ; Re = V D / ν
Re < 2000 : λ = 64/Re ; sinon λ = 0,25 / [log₁₀(ε/(3,7 D) + 5,74/Re^0,9)]² (Swamee-Jain)
ΔH_lin = λ (L/D) V²/(2g) ; ΔH_sing = ΣK V²/(2g)

Assumptions

  • Water at ~20 °C (ν ≈ 1.004×10⁻⁶ m²/s). Swamee-Jain matches Colebrook-White within ~1% for 10⁻⁶ ≤ ε/D ≤ 10⁻² and 5,000 ≤ Re ≤ 10⁸. Transition zone (2000–4000) is uncertain.

Fill in the inputs and run the calculation: results and every intermediate step will appear here.

These tools provide estimates and calculation aids. They are neither design calculations nor an engineering approval: any design or safety decision must be checked by a qualified professional against the applicable standards.